Car Top Inspection Station
Product Features
· Stainless Steel Seamless NEMA 4X Enclosure
· GFCI Receptacle
· NEMA 4, 12 & 4X Pushbuttons
· Rust and corrosion resistant stainless hardware
· Gasketed Light Bulb Guard
MODELS AVAILABLE
722-303
Car Top Inspection
Station - Complete
w/Worklight and GFCI
Receptacle
When ordering please indicate voltage required.
This is needed so that we can supply the correct
fire service buzzer and lamp.
Car Bottom/Pit Light Station
Product Features
· Stainless Steel Seamless NEMA 4X Enclosure
· GFCI Receptacle
· NEMA 4, 12 & 4X Pushbuttons
· Rust and corrosion resistant stainless hardware
· Gasketed Light Bulb Guard
MODELS AVAILABLE
NEMA 4X-Water/Corrosion Resistant
722-305
Worklight & Receptacle
Only
Pit Flood/Float Sensor
Please note that this device is simply a water
sensor contact and does NOT contain the logic,
circuitry, or relays to actually run the elevator.
You may need to add relays or additional
circuitry to your controller in order for pit flood
service to work correctly.
Steps that should happen if water is sensed in
the pit and this device is activated should
include the following based on our
recommendation.
Recommended Operation
With pit flood device mounted 1"-2" from pit
floor the following sequence of operations
should occur. CJA Controllers from 2010 and
above have Pit Flood Circuitry Built In.
1. Pit Flood Sensor Rises and Closes
Contact.
2. Closing Contact Connects Back To
Controller
3. Elevator Runs To Top Floor, Doors
Open and Stay Open
4. All Hall Calls and Car Floor Buttons
are Disabled
5. Fault Code On Controller Pit Flood
Cannot be Cleared Until Elevator Is
Checked By Mechanic/Inspector.
IMPORTANT NOTE: The sequence of
operation mentioned above is something that
2010 and newer CJA Elevator Control
Systems have built into the programming. If
your controller is older and/or manufactured
by another company, it may not be able to
perform the tasks indicated above. We
recommend that at the very least you are
able to add relays so that the elevator runs to
the top floor if the float switch is activated
and stays at the top floor, disabling all car
and hall calls until the elevator can be
inspected by a trained elevator mechanic.
Product Features
Control Interface Options
0.40A @ 240 VAC · 0.20A @ 120 VDC
0.50A @ 120 VAC · 0.50A @ 24 VDC
MODELS AVAILABLE
NEMA 4X-Water/Corrosion Resistant
51101-PF
Pit Float Sensor
Ordering Information
Light Switch & GFCI Receptacle
Sorry, light bulb not included!