background image
73
A
LPHA
B
ASIS
- 230 V
OLT
A
LPHA
B
ASIS
- 24 V
OLT
Features
· 2-minute switch-on delay
· Follow-up time optionally selectable
· Pump protection by interval switching
· Functional design
· Modular plug-in installation
· Spring/clamp terminal connection
technique
· Second connection for electric consumer
3308999: Alpha Basis Pump Module AB PD2000
Features
· 2 channel digital clock
· 42 memory locations
· Automatic switching between
summer and winter time
· Power reserve: approximately 30 days
· Simple operation by LCD text line
· Functional design
1361333: Alpha Basis Timer Module AB TM 1000
1042006: Alpha Basis Quick Mount panel 24v-40006N
Features
· Operating mode indicators
(voltage supply, fuse)
· Function indicator
(operating condition of thermostats)
· Connection by screwless
spring/clamp terminal connection
· Clear arrangement of the
connection line with cable grip
· Extendible modular
1912246: Alpha Basis Quick Mount panel 24v-40001N
Features
· Operating mode indicators
(voltage supply, fuse)
· Function indicator
(operating condition of thermostats)
· Connection by screwless spring/clamp
terminal connection
· Clear arrangement of the
connection line with cable grip
· Extendible modular
TECHNICAL DATA
Operating voltage
230 V AC / 24 V AC
Switching voltage / switching current 24 V AC/DC , 230 V AC, 5 A
Dimensions (mm) H / W / L
70 / 75 / 88
Weight
210 g
Protection class
II
Protection type
IP 20
Ambient temperature
0 to 50°C
Storage temperature range
-25 to 60°C
Relative humidity
max. 80%1)
Solid wire
0.5 -1.5 mm²
Flexible wire
2)
1.0 -1.5 mm²
TECHNICAL DATA
Operating voltage
230 V~ ±10% 50-60 Hz
Breaking capacity/Channel
230 V/100 mA short-circuit proof
Protection class
II acc. to EN60730
Accuracy
+/- 1 sec/day at 20 °C
Power reserve
30 days after 48 hours charge
Memory locations
42
Shortest switching time
1 minute
Display
alphanumeric LCD display, 5.5 mm high,
with special characters
Pre-set heating programs
yes
Manually on/off
yes
Switching state indication
yes
Special functions
Weekday block formation
Day and week program
Switching between summer and winter time
Dimensions (mm) H / W / L
46 / 75 / 65
Ambient temperature range
-10 to 50°C
Storage temperature range
-25 to 60°C
Relative humidity
max. 80%1)
TECHNICAL DATA
Operating Voltage
230V / 24V AC Secondary
Max. Power Input
50W
Fuse
T 2A H
Max. number of thermostats
6
Max. number of actuators (about 2W) 14
Heating programs (optional)
2
Dimensions (mm) H/W/L
70/75/302
Protection class
II
Protection type
IP 20
Ambient temperature
O to 50°C
Storage temperature
-25 to 60°C
Relative Humidity
Max. 80%
Solid wire
0.5 ­ 1.5 mm²
Flexible wire
1.0 ­ 1.5 mm²
TECHNICAL DATA
Operating Voltage
230V / 24V AC Secondary
Max. Power Input
50W
Fuse
T 2A H
Max. number of thermostats
6
Max. number of actuators (about 2W) 14
Heating programs (optional)
2
Dimensions (mm) H/W/L
70/75/302
Protection class
II
Protection type
IP 20
Ambient temperature
O to 50°C
Storage temperature
-25 to 60°C
Relative Humidity
Max. 80%
Solid wire
0.5 ­ 1.5 mm²
Flexible wire
1.0 ­ 1.5 mm²