background image
System with 1 storage tank and
circulation function
System examples
System with 1 storage tank
System with 1 storage tank and
heat meter
V
System with 1 storage tank and back-up
heating function
39
TEMPERATURE DIFFERENTIAL
SUNTANA
System voltage
230 V (± 15 %), 50 Hz
[optional 115 V (± 15 %), 60 Hz]
Max. own consumption
1 W
Inputs
6
5 x temperature determination
(Pt1000 or KTY81-210)
1 x pulse detection for calorimetry
Output
2
1 x R1 triac for speed control,
max. 200 W [230 V]
1 x R2 switch output,
max. 800 W [230 V]
or R2 voltage free
Turn-on temperature difference
4...17 K
Turn-off temperature difference
2...15 K
Operation temperature range
0 °C...+45 °C
Display
LCD-Display
Protection class
IP 20 / DIN 40050
Weight
490 g
Dimensions l x w x h
150 x 215 x 44 mm
6
INPUTS
2
OUTPUT
Steca Suntana
The Suntana solar thermal controller is another member
of our solar controller family. The controller monitors
and controls solar thermal energy systems with a collector
array, a storage tank and alternatively with an appropriate
back-up heating or circulation pump. Apart from controlling
the solar system, the controller also performs important
system monitoring and safety functions. The system
parameters and measured values can be viewed and modified
via a 2 x 16-digit menu-driven LCD-Display.
The amount of solar energy fed from the collector array into
the storage tank can be read from the LCD Display at any time,
thanks to a flow meter with pulse output. The controller has
a maximum of five inputs for temperature measurement, a
digital pulse input for recording heat volume data, and two
outputs for controlling pumps. A programmable timer with
selectable switching times for controlling a solar circuit pump
is integrated into the unit. Installation mistakes are avoided
from the very beginning through the automatic recognition of
the temperature sensors. The components delivered with the
controller include a collector temperature sensor and two
storage tank sensors.
Features
· Easy operation by menu-driven LCD-Display
· Time and temperature dependent control of
circulation control
· Adjustable cooling and back-up heating function
· Software-controlled collector cooling function
· Speed control of solar circuit pump
· Limitation of storage tank temperature
· Temperature sensor monitoring and fault
analysis
· Logging of solar circuit pump operating hours
· Minimum and maximum displays of the storage
tank and collector temperatures
· Automatic recognition of the Pt1000 or KTY
temperature sensors
· Measurement and logging of heat volumes
TECHNICAL DATA
215
44
152
kWh
BHF
Collector
1st. tank
SOLAR THERMAL CONTROLS
Solar Brochure EXTRA:Layout 1 19/02/2010 12:54 Page 39