AIR SEPARATOR
Installation
The air separators must be installed on horizontal piping lines and
in the horizontal position, so that the air accumulates in their upper
part. The separator also includes wall-mounting accessories
SAFETY VALVES
Description
The purpose of solar safety valves with solar membranes is to
limit the pressure in the primary circuit of solar heating systems.
They also include a lever for manual draining.
Technical characteristics
Maximum working temperature: 160ºC.
Fluid: 50% water-glycol mixture.
Connections: "H- "H.
Ethylene-propylene seal and membrane.
Special stamped brass valve body, in accordance with
EN 12165 standards.
Spring with antioxidant treatment.
Calibration pressures: 3, 4, 6, 8, 10 bar.
Certification for solar safety valves:
TÜV SV 07 2012 · SOL · 50 · p.
Installation
Safety valves must be installed in vertical or horizontal position,
and never inverted (with the lever facing downwards). No elements
isolating the valve from the rest of the system are to be installed.
It is also recommendable to provide for a fluid collection device at
the outlet, to catch any drips of water and anti-freeze mixture.