99
DELTA CYLINDERS
Unvented Stainless Steel
Cylinder Data Sheet
VOLUME
SINGLE COIL
DOUBLE COIL
TRIPLE COIL
STANDING
HEAT LOSS
090 litre
1 x 0.582m
1.02kW/24hrs
125 litre
1 x 0.582m
1.7kW/24hrs
150 litre
1 x0.582m
1.9kW/24hrs
170 litre
1 x 0.672m
1 x 0.582m
1 x 0.672m
3 x 0.582m
2.04kW/24hrs
200 litre
1 x 0.672m
2 x 0.582m
3 x 0.582m
2.45kW/24hrs
250 litre
1 x 0.772m
1 x 0.582m
1 x 0.672m
3 x 0.582m
2.69kW/24hrs
300 litre
1 x 0.772m
1 x 0.582m
1 x 0.672m
3 x 0.582m
2.71kW/24hrs
400 litre
1 x 1.022m
1 x 0.582m
1 x 0.772m
1 x 0.582m
2 x 0.772m
3.19kW/24hrs
500 litre
1 x 1.282m
1 x 0.582m
1 x 0.772m
1 x 0.582m
2 x 0.772m
3.25kW/24hrs
Volume (Litre)
Weight when full
(Kg)
Heat Up
15OC to 60
O
C
(mins
Reheat to 60
O
C after
70% draw off
(mins)
90
125
26
18
125
165
36
25
150
195
37
26
170
220
36
25
200
250
33
24
250
310
35
25
300
360
40
29
400
449
47
34
500
556
54
39
Heat up and re-heat times are for comparative purposes and assume an incoming cold water temperature of 15
O
C
and an adequate energy input. Times are given for indirect models operating on one coil only.
All dimensions, weights and times are nominal and subject to change without prior notice.
ELTA
STAINLESS STEEL UNVENTED CYLINDERS
Solar Brochure EXTRA:Layout 1 19/02/2010 12:58 Page 99