- Page 2 - Page 3 - Page 4 - Page 5 - Page 6 - Page 7 - Page 8 - Page 9 - Page 10 - Page 11 - Page 12 - Page 13 - Page 14 - Page 15 - Page 16 - Page 17 - Page 18 - Page 19 - Page 20 - Page 21 - Page 22 - Page 23 - Page 24 - Page 25 - Page 26 - Page 27 - Page 28 - Page 29 - Page 30 - Page 31 - Page 32 - Page 33 - Page 34 - Page 35 - Page 36 - Page 37 - Page 38 - Page 39 - Page 40 - Page 41 - Page 42 - Page 43 - Page 44 - Page 45 - Page 46 - Page 47 - Page 48 - Page 49 - Page 50 - Page 51 - Page 52 - Page 53 - Page 54 - Page 55 - Page 56 - Page 57 - Page 58 - Page 59 - Page 60 - Page 61 - Page 62 - Page 63 - Page 64 - Page 65 - Page 66 - Page 67 - Page 68 - Page 69 - Page 70 - Page 71 - Page 72 - Page 73 - Page 74 - Page 75 - Page 76 - Page 77 - Page 78 - Page 79 - Page 80 - Page 81 - Page 82 - Page 83 - Page 84 - Page 85 - Page 86 - Page 87 - Page 88 - Page 89 - Page 90 - Page 91 - Page 92 - Page 93 - Page 94 - Page 95 - Page 96 - Page 97 - Page 98 - Page 99 - Page 100 - Page 101 - Page 102 - Page 103 - Page 104 - Page 105 - Page 106 - Page 107 - Page 108 - Page 109 - Page 110 - Page 111 - Page 112 - Flash version © UniFlip.com |
RA DIOP H A RMACY
PORTABLE SHIELDED ISOLATOR
Certified Shielded Barrier Laminar Flow Isolator
• • • • • • • • • • • • • • • • • Small footprint Antechamber located under the Isolator Large, full-view shielded window Designed from the ground up for a Radiopharmacy Stainless Steel, inside and out Motorized height adjustable – 10 inch range Work sitting or standing-with correct ergonomics Meets USP Radiopharmaceuticals – Preparation, Compounding, Dispensing and Repackaging Guidelines Internal IV bar Sealed shielded dose calibrator chamber in the work surface Fits most dose calibrators Use for blood work or other compounding or drawing requirements Mobile, on four heavy-duty locking casters Electric outlets in work area HEPA air filtration Lead shielded (.25" thick) for compounding mid to low-energy sterile radiopharmaceuticals ISO Class 5 (Class 100) Isolator
The Cleanroom Solution The Biodex Germfree Shielded Isolator provides the ultimate in both product and operator protection. The shielded isolator functions as a “glovebox” using negative pressure to meet NIOSH recommendations while complying with USP<797> and <825> regulations for use outside a cleanroom. HEPA filtered unidirectional (laminar) air bathes the work area to protect the product from contamination and removes any particulate generated by sample manipulation. The operator is provided a complete shielded barrier from materials being manipulated in the work area. The Biodex Germfree Shielded Isolator meets or exceeds ISO 14644-1, ISO Class 5 (Class 100) air quality. Each shielded isolator undergoes rigorous physical testing to assure the unit meets performance requirements as validated. It is required that independent certification be performed before use. What is a Barrier Laminar Flow Isolator? According to the Food and Drug Administration, a barrier isolator is “a decontaminated unit supplied with HEPA filtered air that provides uncompromised continuous isolation of its interior from the external environment, including surrounding cleanroom air and personnel.” By installing a certified barrier isolator, one can obtain cleanroom conditions within a contained workspace. Barrier isolators provide a ISO Class 5 (Class 100) environment for product preparation, with work occurring inside a closed, pressurized environment accessible only via sealed gloves that reach into the work area.
A Shielded Glovebox is not a certified barrier isolator. By choosing a certified barrier isolator, the requirement for an ISO Class 8 environment is eliminated. The Biodex Germfree Isolator is an excellent example of a well-designed shielded barrier Laminar Flow Isolator, meeting all standards and more. Antechamber • Sealed two-door air lock maintains complete environmental separation between work area and ambient conditions. • HEPA filtered purge of trapped air-lock air eliminates cross contamination between the work area and the room during both material ingress and egress. Filtration • Full framed, standard size mini-pleat HEPAs filter 100% of inlet and exhaust air from both the work area and the antechamber to provide a fully contained environment. • HEPA filters are full coverage and front loading for easy replacement by a certifier. Ergonomics • Hydraulic assist height adjusting stand offers a full 10" range, allowing operators to sit or stand comfortably for extended time periods.
52 Biodex Medical Systems, Inc. • www.biodex.com
|