DOSE CA L IBRAT ION ATOMLAB™ WIPE TEST COUNTER Eliminate the tedium of wipe testing UPGRADE-ABILITY The Atomlab™ Wipe Test Counter can be upgraded to include a fully functioning Atomlab™ Dose Calibrator simply by adding a new chamber. The “Smart Display” detects which chambers are connected and instantly reconfigures the screen to the appropriate icons. • Windows® 10 Operating System • Microsoft SQL Database • Communicates with most commercially available NM management systems • USB connectivity for external monitor, printer, and software upgrades • 64 Channel MCA • Expandable library of 33 commonly used isotopes • Adjustable wide window and individual isotopes • 2x2 NaI drilled-well detector • Remote shielded well • Energy spectrums with individual ROI • Ability to help identify isotopes causing contamination • Wipe testing results stored • User-specific wipe locations and trigger levels • Wipes that exceed trigger levels are immediately recognized • Detailed wipe reports including cpm and dpm • Upgradable at any time to a dose calibrator by adding an ionization chamber • Report printer available • Two-year warranty Standard Apps for Atomlab Wipe Test Counter include: • Automated Quality Assurance Apps - Full Width at Half Max (FWHM) - Chi Square - Minimum Detectable Activity (MDA) • NEW Manual MCA Program T he Atomlab™ Wipe Test Counter is easy to use, easy to understand, fast and dependable. A color touchscreen display utilizing intuitive software eliminates the tedium of wipe testing. Simply perform a daily calibration and background count, then count the wipe for each predetermined location. Trigger levels can be set for any isotope at any location including 200 dpm for iodine. In seconds the system will determine if the location is above or below the user defined trigger level. When performing a wipe test, the full spectrum is displayed. A wide window that includes the isotope energies expected in a particular department is set by the user. The efficiencies of the isotopes selected for the window can be either factory defaults or user determined using an integrated detector efficiency program. Individual isotope ROIs along with the wide window can be set. This feature helps identify the isotope(s) causing contamination. The user may define an unlimited number of “Area” names and wipe “Locations” and designate them as restricted area, unrestricted area, sealed source or package. The Wipe Test Program automatically calculates net contamination levels and reports results in dpm, uCi and Bq. The system consists of a lead shielded 2" x 2" sodium iodide NaI (Tl) well detector and a 64 channel multichannel analyzer. The displayed energy range (spectrum) is 0-800 KeV, which is typically found in nuclear medicine departments. The wipe counter is designed to meet or exceed all NRC (10 CFR 35.70, 10 CFR 20.1906 and 10 CFR 35.2067) and state wipe test requirements. There are automated programs for the quality assurance functions: calibration, FWHM, chi-square and minimum detectable activity (MDA). Wipe test results and QA test data can be stored in memory and printed at any time. 58 Biodex Medical Systems, Inc. • www.biodex.com