- Page 2 - Page 3 - Page 4 - Page 5 - Page 6 - Page 7 - Page 8 - Page 9 - Page 10 - Page 11 - Page 12 - Page 13 - Page 14 - Page 15 - Page 16 - Page 17 - Page 18 - Page 19 - Page 20 - Page 21 - Page 22 - Page 23 - Page 24 - Page 25 - Page 26 - Page 27 - Page 28 - Page 29 - Page 30 - Page 31 - Page 32 - Page 33 - Page 34 - Page 35 - Page 36 - Page 37 - Page 38 - Page 39 - Page 40 - Page 41 - Page 42 - Page 43 - Page 44 - Page 45 - Page 46 - Page 47 - Page 48 - Page 49 - Page 50 - Page 51 - Page 52 - Page 53 - Page 54 - Page 55 - Page 56 - Page 57 - Page 58 - Page 59 - Page 60 - Page 61 - Page 62 - Page 63 - Page 64 - Page 65 - Page 66 - Page 67 - Page 68 - Page 69 - Page 70 - Page 71 - Page 72 - Page 73 - Page 74 - Page 75 - Page 76 - Page 77 - Page 78 - Page 79 - Page 80 - Page 81 - Page 82 - Page 83 - Page 84 - Page 85 - Page 86 - Page 87 - Page 88 - Page 89 - Page 90 - Page 91 - Page 92 - Page 93 - Page 94 - Page 95 - Page 96 - Page 97 - Page 98 - Page 99 - Page 100 - Page 101 - Page 102 - Page 103 - Page 104 - Page 105 - Page 106 - Page 107 - Page 108 - Page 109 - Page 110 - Page 111 - Page 112 - Flash version © UniFlip.com |
DOSE CA L IBRAT ION
LINEATOR
Simulates eight different source strengths — using only one source
MOLY ASSAY SHIELD
M
oly Assay Shields are a convenient method to verify a unit dose. Whether working with syringes or vials, either unit will fit into the well chamber of any Atomlab Dose Calibrator. The leaded shields are cradled by a metal holder for easy handling to ensure proper placement inside the chamber.
Model 086-435 shown
SPECIFICATIONS:
• Simplifies compliance with NRC and state requirements • Checks linearity without sample decay or fractioning • Covers diagnostic or therapeutic quantities in a single pass
086-435 Moly Assay Shield, Syringe Dimensions: 9.125" h x 2.125" dia (23.2 x 5.4 cm) Lead Shielding: .3" thick (7.6 mm) 086-423 Moly Assay Shield, Vial Dimensions: 3.5" h x 2" dia (8.9 x 5.1 cm) Lead Shielding: .3" thick (7.6 mm)
086-435 086-423
T
he Lineator is a simple device to accurately and reliably verify the linearity of your dose calibrator. Test results are available in minutes, without waiting days for decay, making it feasible to perform a linearity test more often. Early identification can prevent problems before they occur. The Lineator is a set of five tubes. Four tubes are used to perform the test and an interchangeable tube is used depending on the dynamic range needed to cover. To perform a linearity test, insert a source of Tc-99m of the maximum activity to be measured into the central tube, then place the tube into the chamber of your dose calibrator and count. The remaining lead-lined tubes are placed, one at a time, concentrically over the central tube and counted individually or in combination. The readings are then normalized with predetermined factors, and the degree of linearity can be seen virtually at a glance. Using only one source, the Lineator can simulate up to eight different source strengths. Each outer tube absorbs a portion of the source radiation and reduces the effective source activity seen by the dose calibrator.
SPECIFICATIONS:
Moly Assay Shield, Syringe, .3" lead Moly Assay Shield, Vial, .3" lead
NEW
VIAL/SYRINGE DIPPER
T
his durable Vial/Syringe Dipper has a comfortable handle and accommodates 1 cc to 10 cc syringes or up to a 30 ml vial. Included with each Atomlab Dose Calibrator, the dipper will also fit any well chamber with 2.5" x 10" interior dimension. The low attenuation acrylic is resistant to breakage.
Weight: 6 lb (3 kg)
086-509
Lineator
086-242
Dipper, Vial/Syringe
62 Biodex Medical Systems, Inc. • www.biodex.com
|