- Page 2 - Page 3 - Page 4 - Page 5 - Page 6 - Page 7 - Page 8 - Page 9 - Page 10 - Page 11 - Page 12 - Page 13 - Page 14 - Page 15 - Page 16 - Page 17 - Page 18 - Page 19 - Page 20 - Page 21 - Page 22 - Page 23 - Page 24 - Page 25 - Page 26 - Page 27 - Page 28 - Page 29 - Page 30 - Page 31 - Page 32 - Page 33 - Page 34 - Page 35 - Page 36 - Page 37 - Page 38 - Page 39 - Page 40 - Page 41 - Page 42 - Page 43 - Page 44 - Page 45 - Page 46 - Page 47 - Page 48 - Page 49 - Page 50 - Page 51 - Page 52 - Page 53 - Page 54 - Page 55 - Page 56 - Page 57 - Page 58 - Page 59 - Page 60 - Page 61 - Page 62 - Page 63 - Page 64 - Page 65 - Page 66 - Page 67 - Page 68 - Page 69 - Page 70 - Page 71 - Page 72 - Page 73 - Page 74 - Page 75 - Page 76 - Page 77 - Page 78 - Page 79 - Page 80 - Page 81 - Page 82 - Page 83 - Page 84 - Page 85 - Page 86 - Page 87 - Page 88 - Page 89 - Page 90 - Page 91 - Page 92 - Page 93 - Page 94 - Page 95 - Page 96 - Page 97 - Page 98 - Page 99 - Page 100 - Page 101 - Page 102 - Page 103 - Page 104 - Page 105 - Page 106 - Page 107 - Page 108 - Page 109 - Page 110 - Page 111 - Page 112 - Flash version © UniFlip.com |
T H YROID UPTA K E SYST EM
COMPREHENSIVE CLINICAL SOFTWARE
Extremely intuitive menus follow conventionally established nuclear medicine procedures. All programs provide clear, concise reports for referring physicians, insurance providers, patient records and a database for physician and technologist identification. PDF reports allow for easy electronic distribution.
THYROID UPTAKE PROGRAM
ADMINISTRATION/QUALITY ASSURANCE PROGRAM
• Automatic daily calibration using Cs-137 source • Automatic high voltage adjustment • Automatic Chi-Square test, with report • Automatic MDA calculation • Administration summary QA report • Isotope efficiency calculations
T
• Supports multiple time-stamped uptake measurements • Auto decay correction • User-defined uptake protocols • On-screen spectrum acquisition and analysis • Reports include normal ranges, notes/comments, facility/physician/technologist
here are a multitude of administration functions, each designed to minimize the time normally spent maintaining accurate use of the system. There is an automated high voltage setting for each detector, and an automatic calibration program using a Cs-137 source. The system will advise the user when a daily calibration has not been performed. The ChiSquare test program automatically performs the Chi-Square calculations and generates a printed report. Site information is entered in the administration program containing the facility name, address, and a list of the technologists and physicians in the department. Customized administrative and clinical reports can be printed or saved in PDF format.
T
he Atomlab 960 provides intuitive menus with provision to modify any procedure to suit specific requirements. Atomlab software guides the user through each step of any defined procedure. Automatic decay correction calculates elapsed time between dose count and actual patient thyroid count, and then automatically computes uptake percentage.
MANUAL MCA PROGRAM
For performing sample counts and analysis beyond the scope of the standardized programs. • Expandable library of 28 commonly used isotopes • Unlimited user-defined isotopes • Three counting methods: Preset Time, Preset ROI, and Continuous Counting
I
n addition to providing “standardized” programs for routine test and survey procedures, the 960 has a “manual” program to accommodate other counting and spectrum analysis tasks. The user can select from three counting methods: Preset Time, Preset ROI Count, and Continuous Counting. After any count, the Spectrum Analysis option can be used to produce a Spectrum Analysis Report. The monitor shows when a test is in progress and graphically displays the spectrum, time, counts and cpm.