SOURC ES DOSE CALIBRATOR VIAL REFERENCE SOURCES* he daily calibration of dose calibrators is recommended to ensure accurate and reproducible instrument response. Calibration is easily achieved and maintained by the use of long-lived reference sources. These sources are solid cast epoxy, 20 ml active volume in the 27 ml Vial E. They are calibrated with ±5% accuracy at the 99% confidence level, NIST traceable. Dose Calibrator Reference Sources are registered with the U.S. Food and Drug Administration Center for Devices and Radiological Health and the U.S. Nuclear Regulatory Commission. Each source includes a certificate of calibration, a leak test certificate, and a radiation safety and handling sheet. The source is packaged in an individual lead shield that is color coded and vinyl covered to eliminate exposure to the lead. Dose Calibrator Reference Sources are available individually or as an economical set. Vial Dose Calibrator Reference Sources: All sources calibrated to ±5% 063-562 Source, Ba-133, 250 µCi 063-350 Source, Co-60, 50 µCi 101-356 Source, Cs-137, 200 µCi 063-261 Source, Co-57 simulated Tc-99m, 5 mCi 063-720 Source, Co-57 simulated Tc-99m, 10 mCi 063-586 Reference Source Set Set includes: Co-57, 5 mCi; Cs-137, 200 µCi; Ba-133, 250 µCi Not available for export. Reference: 1. Guide for Preparation of Application for Medical Programs, U.S. Nuclear Regulatory Commission, Regulatory Guide 10.8 and American National Standard, Calibration and Usage of "Dose Calibrator" Ionization Chambers for the Assay of Radionuclides, ANSI N-42. 13-1986. DOSE CALIBRATOR SYRINGE REFERENCE SOURCES* he daily calibration of your dose calibrator is recommended to ensure accurate and reproducible instrument response. Calibration, using long-lived standards, should be performed in a manner that most closely represents how you use your dose calibrator. The Dose Calibrator Syringe Reference Source was designed for imaging facilities that obtain their radiopharmaceuticals in unit dose syringes. The sources are solid cast epoxy, 3 ml active volume in a 5 cc “mock” syringe. They are calibrated within ± 5% accuracy at 99% confidence level, NIST traceable. Each source includes a certificate of calibration, leak test certificate, and radiation safety and handling sheet. The source is packaged in an individual lead shield that is color coded to the source. Dose Calibrator Syringe Reference Sources are available individually or as an economical set. Syringe Dose Calibrator Reference Sources: All sources calibrated to ± 5% 063-361 Source, Ba-133, 250 µCi 063-360 Source, Cs-137, 200 µCi 063-362 Source, Co-57, 5 mCi 063-364 Source, Ge-68, Simulated F-18,500 µCi 063-363 Syringe Source Set Set includes: Ba-133, 250 µCi; Co-57, 5 mCi; Cs-137, 200 µCi Not available for export. T T ROD SOURCES* T o calibrate well type scintillation crystals, Biodex offers a variety of Rod Sources to meet department needs. You can count on consistent accuracy. Rod Sources are calibrated as NIST traceable with an accuracy of ±5% at the 95% confidence level. nEw SPECIFICATIONS: Dimensions: 2.96" l x 0.47" dia (76 x 11.9 mm) Nominal Total Activity: 0.1 µCi Rod Source, Ba-133 Rod Source, Cs-137 063-137 Rod Source, Co-57 063-140 Rod Source, Ge-68 simulated F-18 063-100 Rod Source Set Set includes: Ba-133, Cs-137, Co-57, Na-22, Mn-54, Co-60 and Cd-109 Not available for export. 063-138 063-139 FREE DISPOSAL whEn you puRchasE a REFEREncE souRcE FRom biodEx (Applies to United States Only) . *A photocopy of your NRC or Agreement State License must accompany orders for radioactive sources and must clearly indicate your authority to possess the source being ordered. 82 Biodex Medical Systems, Inc. • www.biodex.com